Inductively coupled plasma mass spectrometry (ICP-MS) is a new analytical technique developed in the 1980s. Its interface technology combines the high-temperature (7000K) ionization characteristics of ICP with the sensitive and rapid scanning advantages of quadrupole mass spectrometers to form a new type of elemental and isotope analysis technology, capable of analyzing almost all elements on Earth. The analytical capabilities of ICP-MS can not only replace traditional inorganic analysis techniques such as inductively coupled plasma optical emission spectrometry (ICP-OES) and graphite furnace atomic absorption spectrometry (GFAAS) for qualitative, semi-quantitative, quantitative analysis, and accurate measurement of isotope ratios, but also can be coupled with other technologies such as high-performance liquid chromatography (HPLC), high-performance capillary electrophoresis (HPCE), and gas chromatography (GC) to analyze elemental speciation, distribution characteristics, etc. With the rapid development of this technology, it has been widely used in environmental analysis, semiconductor industry, medicine, biology, metallurgy, petroleum, nuclear materials analysis and other fields. As a major driving force for scientific and technological progress, universities and research institutions play an irreplaceable role in the application development and popularization of ICP-MS technology.

Related ProductsView All Products

iQuad a/2300 Series ICP-MS
  • Robust Performance
  • Analytical Stability
  • 4-hour long-term stability RSD < 3%
  • High Throughput
  • 7-port valve high-speed sampling
  • Intelligent electronic dilution
  • Accurate Analysis
  • Axial acceleration hexapole collision/reaction cell
  • Optimized ion transmission path
  • Smart Software
  • Remote control & one-click start
  • Automatic tuning
  • Advanced features
iQuad 2300P Fully Automatic Element Analysis System
  • Full process control, fully automatic analysis
  • Building upon intelligent microwave digestion technology, the system integrates with an ICP-MS analytical platform to achieve complete end-to-end automation.
  • The fully automated process includes acid addition, sample loading, digestion, cooling, dilution, homogenization, sample solution transfer, and ICP-MS auto-triggered analysis, enabling high-throughput automated sample analysis.”
  • High analytical throughput
  • Fully automatic analysis of more than 200 samples per day
  • Three independent microwave oven cavities can run three different heating programs at the same time, which can increase the work efficiency by 10 times and greatly speed up the scientific research process.
  • Robust analytical performance
  • The microwave robot has 96 sample positions, and each digestion tank can withstand 45 Bar pressure and 240°C temperature, which truly realizes high-pressure and high-throughput microwave digestion and has strong sample processing capabilities.
  • The ICP-MS part is well-known in the industry for its “robust performance”. Its long-term stability and collision cell have strong performance in reducing interference, and its performance is impressive.
  • Remote monitoring, unattended operation
  • 2300P has remote monitoring function. Users can monitor the instrument remotely through mobile phone APP to reduce manpower and realize unattended work.

 